Area Aerosol Monitors and Dust Monitors
With an area dust monitor you'll never have to wait for laboratory results to assess whether airborne pollutants have reached dangerous levels. These instruments were formerly manufactured by MIE and Thermo Andersen.
Thermo Scientific DR-4000
Area Dust Monitoring
With the DataRAM DR 4000, you’ll never have to wait for laboratory results to assess whether airborne pollutants have reached dangerous levels. It measures mass concentrations of airborne dust, smoke, mist, haze, and fumes as well as air temperature and humidity. The DataRAM DR4000 allows for simultaneous real-time sample collection.
Features
- PM10 and PM2.5 monitoring
- Internal Datalogging
- Rechargeable battery
- Programmable alarm
- Internal diaphragm pump
- Internal zero and span checks
Specifications
- Range 0.1 g/m³ to 399.9 mg/m³
- Particle size of max. response 0.1 to 10m
- Capacity 10,000 points
- 24 hour runtime (unlimited on AC power)
- Alarm range 0.1 g/m³ to 399.9 mg/m³
- Sample flow rate 1.7 to 2.3 L/m
- Weight 11.7 pounds
Ranges
Autoranging
- 0.1 to 999.9 g/m³, resolution 0.1g/m³
- 1.0 to 39.99 g/m³, resolution 0.01mg/m³
- 40 to 399.9 mg/m³, resolution 0.1mg/m³
Temperature
- 5 to 140°F, accuracy 32.09°F
Humidity
- 0 to 100% (accuracy 2%: noncondensing)
Thermo Scientific DR-2000
Area Dust Monitoring
The DataRAM DR 2000 measures mass concentrations of dust, smoke, mists, haze, and fumes and provides continuous real-time readouts. Large capacity datalogging lets you save data for future analysis. The DataRAM DR2000 allows for simultaneous real-time sample collection.
Features
- PM10 and PM2.5 monitoring
- Internal Datalogging
- Rechargeable battery
- Programmable alarm
- Internal diaphragm pump
- Internal zero and span checks
Specifications
- Range 0.1 g/m³ to 399.9 mg/m³
- Particle size of max. response 0.1 to 10m
- Capacity 10,000 points
- 24 hour runtime (unlimited on AC power)
- Alarm range 0.1 g/m³ to 399.9 mg/m³
- Sample flow rate 1.7 to 2.3 L/m
- Weight 11.7 pounds
Ranges
Autoranging
- 0.1 to 999.9 g/m³, resolution 0.1g/m³
- 1.0 to 39.99 g/m³, resolution 0.01mg/m³
- 40 to 399.9 mg/m³, resolution 0.1mg/m³
Thermo Scientific ADR-1200S
Real-Time Ambient Dust Monitoring
The Model ADR 1200S is a particulate monitoring system designed for outdoor operation. Its weatherproof enclosure ensures safe and effective operation under a wide range of ambient environmental conditions. The ADR1200S is designed for continuous unattended monitoring providing, real-time data transmission to a central location and/or internal data logging. Data logging is incorporated in the system or real-time data transmission can be achieved via Thermo Electron's pDR-COM software or a third party modem, or telemetry equipment. Real-time STEL values can be displayed on the ADR 1200S.
The ADR 1200S incorporates the proven and highly successful light scattering photometry sensing technology for which Thermo Electron is known worldwide. Long-term, precise and driftless measurements of airborne particulate matter concentrations down to 0.001 mg/m³ are assured by a unique combination of optical sensing and electronic signal processing techniques. This method has been refined over the last 25 years.
The ADR-1200S can be used for particle size-selective measurements using the metal cyclone (included). The cyclone is the preferred method for measuring respirable articulates
or to obtain information on particle size distribution (by varying the sampling flow rate). In addition to the real-time/continuous measurements by light scattering, the system enables the user to collect the sampled particles on a membrane filter for gravimetric and/or chemical analysis.
Features
- Hazardous remediation monitoring
- Fenceline monitoring
- Ambient monitoring
- Roadside monitoring
- Construction/demolition monitoring
- Steel structure/bridge painting
Specifications
- Operating temperature 14 to 122°F
- Storage temperature -4 to 158°F
- Dimensions 6.9" x 12" x 16"
- Weight: 22 lbs. (without mounting brackets)
- Resolution largest of 0.1% of reading or 0.001 mg/m³
- Data points in memory 13,000
- Readout display LCD 16 characters
- Serial interface RS232, 4800 baud
- Analog signal output 0 to 5V and 4 to 20mA*
- Power @ 115 Vac. 50 to 300 mA @ 9Vdc
- Enclosure rating NEMA 4
- Electromagnetic/static certification CE
Ranges
Concentration measurement range (auto-ranging)
Scattering coefficient range
- 1.1 x 10-6 to 0.6 m-1 (approximately) @ ? = 880 nm
Precision/repeatability (2-sigma - at constant temperature)
- +/- 5 ?g/m³3 for 1-sec. averaging
- +/- 1.5 ?g/m³3 for 10-sec. averaging
Accuracy
- +/- 5% of reading +/- precision
Particle size range of maximum response
Concentration display updating interval
Alarm level adjustment range (user selectable)
- selectable over entire measurement range
Alarm averaging time (user selectable)
- Instantaneous or STEL (15 min.)
Data logging averaging periods (user selectable)
Specifications for the pDR-PU Attachable Pump Module
- Flow rate (user adjustable): 1 to 5 L/min. (4 nominal)
- Maximum pressure drop: 10 in H2O (25 mbar) @ 2 L/min.
- Precision of constant flow rate control: +/- 2%
Specifications for the pDR-BP Rechargeable Battery Pack
- Rated capacity @ 68?F (20?C): 1.9 ampere-hrs.
- Full charging time: 2 hrs.
Operating time to power the pDR-1200 & pDR-PU@ 68?F
- (20?C) @ 1.5 Lpm: 36 hrs. (typical)