Landfill Gas Analyzers
These landfill gas analyzers can be relied upon to give you accurate gas concentration data for one day or several months.
CES Landtec GEM 2000 Plus
CO2/CH4/LEL/O2/H2S/CO/Pressure
The GEM2000 Plus gives you all the features of the GEM2000 landfill gas monitor, plus built-in detection of Hydrogen Sulfide (H2S) and Carbon Monoxide (CO). You no longer need to store, carry and use external gas pods.
Features
- Fast Calibration
- NiMH or Alkaline Batteries
- Built in datalogger
- Built in pump
- Easy to read display
- Built in pressure ports
- Measures Btu content
Specifications
- Operating temperature 32 to 104°F
- 8 hour run on NiMH or Alkaline batteries
- Capacity 900 points
- Sample flow 500 mL/min
- Vacuum up to 80" W.C.
- UL Certified Class 1, Zone 1
- Weight approx. 5 pounds
Ranges
CH4
- 0 to 100% Vol. in 0.1% steps
LEL
O2
- 0 to 30% Vol. in 0.1% steps
CO2
- 0 to 60% Vol. in 0.1% steps
H2S
CO
Pressure
- Differential 0 to 10" W.C.
- Static 0 to 100" W.C.
CES Landtec GEM 2000
CO2/CH4/LEL/O2/Pressure
The GEM 2000 is designed for analyzing LFG composition and calculating flow. It is certified Intrinsically Safe and offers speed and accuracy.
Features
- Fast Calibration
- NiMH or Alkaline Batteries
- Built in datalogger
- Built in pump
- Easy to read display
- Built in pressure ports
- Measures Btu content
Specifications
- Operating temperature 32 to 104°F
- 8 hour run on NiMH or Alkaline batteries
- Capacity 900 points
- Sample flow 500 mL/min
- Vacuum up to 80" W.C.
- UL Certified Class 1, Zone 1
- Weight approx. 5 pounds
Ranges
CH4
- 0 to 100% Vol. in 0.1% steps
LEL
O2
- 0 to 30% Vol. in 0.1% steps
CO2
- 0 to 60% Vol. in 0.1% steps
Pressure
- Differential 0 to 10" W.C.
- Static 0 to 100" W.C.
CES Landtec GEM 500
CO2/H2S/LEL/O2
The GEM 500 is a solid waste industry standard used to analyze gas content and determine flow from LFG collection wellheads.
Features
- Fast Calibration
- NiMH or Alkaline Batteries
- Built in datalogger
- Built in pump
- Easy to read display
- Built in pressure ports
- Measures Btu content
Specifications
- Operating temperature 32 to 104°F
- 8 hour run on NiMH or Alkaline batteries
- Capacity 900 points
- Sample flow 500 mL/min
- Vacuum up to 80" W.C.
- UL Certified Class 1, Zone 1
- Weight approx. 5 pounds
Ranges
CO2
- 0 to 20% Vol. in 0.1% steps
H2S
LEL
ppm
- 0 to 10,000 in 20 ppm steps
O2
CES Landtec GA 94
CO2/CH4/LEL/O2/Pressure
The precursor to the GEM 2000, the GA94 is a well known instrument within the landfill industry for methane & CO2 detection.
Features
- Fast Calibration
- NiMH or Alkaline Batteries
- Built in datalogger
- Built in pump
- Easy to read display
- Built in pressure ports
- Measures Btu content
Specifications
- Operating temperature 32 to 104°F
- 8 hour run on NiMH
- Capacity 650 points
- Sample flow 500 mL/min
- Vacuum up to 80" W.C.
- UL Certified Class 1, Zone 1
- Weight approx. 4.6 pounds
Ranges
CH4
- 0 to 100% Vol. in 0.1% steps
LEL
O2
- 0 to 30% Vol. in 0.1% steps
CO2
- 0 to 60% Vol. in 0.1% steps
Pressure
- Differential 0 to 10" W.C.
- Static 0 to 100" W.C.
CES Landtec GA 90
CO2/CH4/LEL/O2/Pressure
The precursor to the GEM 2000, the GA90 is a well known instrument within the landfill industry for methane & CO2 detection.
Features
- Fast Calibration
- NiMH or Alkaline Batteries
- Built in datalogger
- Built in pump
- Easy to read display
- Built in pressure ports
- Measures Btu content
Specifications
- Operating temperature 32 to 104°F
- 8 hour run on NiMH
- Capacity 650 points
- Sample flow 500 mL/min
- Vacuum up to 80" W.C.
- UL Certified Class 1, Zone 1
- Weight approx. 4.6 pounds
Ranges
CH4
- 0 to 100% Vol. in 0.1% steps
LEL
O2
- 0 to 30% Vol. in 0.1% steps
CO2
- 0 to 60% Vol. in 0.1% steps
Pressure
- Differential 0 to 10" W.C.
- Static 0 to 100" W.C.
Thermo Gastech Land Surveyor
CH4/H2S/LEL/O2
The GT series detectors is as reliable as always, with an internal pump and datalogging it makes your gas detection job easier.
Features
- Easy calibration
- NiCd or Alkaline D batteries
- Built in datalogger
- Built in pump & flow sensor
- RF resistant housing
- 6 button control
- Peak, STEL, TWA readings
Specifications
- Operating temperature -4 to 113°F
- 12 hr. on NiCd, 24 hr. on Alk. at 68°F
- Capacity 13,000 data sets w/no alarms
- Sample flow 500 mL/min
- Dimensions 10" x 5" x 6"
- UL & CSA Class 1, Groups A, B, C, D
- Weight 5 pounds
Ranges
CH4
- 0 to 100% Vol. in 1% steps
H2S
- 0 to 200 ppm in 1 ppm steps
LEL
ppm
- 0 to 10,000 in 20 ppm steps
O2
RKI Eagle
CH4/LEL/O2/H2S
RKI has made the Eagle with the user in mind; a rugged housing, NiCd or alkaline battery option, datalogging, and auto calibration.
Features
- Auto calibration feature
- NiCd or Alkaline D batteries
- Built in datalogger
- Built in pump & flow sensor
- RF resistant housing
- 6 button control
- Peak, STEL, TWA readings
Specifications
- Operating temperature 14 to 104°F
- 18 hr. on NiCd, 30 hr. on Alk. at 68°F
- Continous operation on AC or DC adapter
- Sample flow 2.0 SCFH
- Dimensions 10.5" x 5.9" x 7"
- UL & CSA Class 1, Groups A, B, C, D
- Weight 5 pounds
Ranges
LEL
- 0 to 100% LEL in 1% steps
O2
- 0 to 40% Vol. in 1% steps
H2S
- 0 to 100 ppm in 1 ppm steps
CH4