Hermit Dataloggers
One of the most recognized names in the water level logging field, In-Situ dataloggers are field proven to be accurate and reliable instruments. Guaranteed in stock!
In-Situ Hermit 3000
8 Channel Datalogger
The new standard for pressure transducer dataloggers! The Hermit 3000 can be programmed from the onboard keypad or via the included WinSitu software.
Features
- Perform multi-well aquifer tests
- Record up to 8 channels
- Barometric sensor built in
- Control pumps with built-in relays
- Download without stopping test
- Network up to 32 units
- View data anytime
- Alkaline battery
- Win-Situ 4.0 software included
- Communication kit included
Specifications
- Operating temp. 14 to 113°F
- Input standard 4–20 mA probes
- Source volt. 20 Vdc, 80 mA max.
- 2 relays, max. 0.5 A @ 115 Vac
- Capacity 475,000 data points
- RS232 communication
- RS422 comm. for networking
- 2 yr. max. runtime
- Dimensions 12" x 10" x 6.75"
- Weight 8.5 lbs.
Ranges
Channels
- 8 external (transducers)
- 1 internal (barometric)
Memory
- 944KB, min. 475,000 points
In-Situ Hermit SE2000
4, 8, & 16 Channel Datalogger
Still a reliable datalogger, the Hermit SE2000 has the advantage of step test capability at the press of a button, which the newer Hermit does not offer.
Features
- 4, 8, or 16 Channels
- Perform multi-well aquifer tests
- Perform Step tests
- Record up to 16 channels
- Linear and Logarithmic tests
- View data anytime
- Alkaline battery (4 and 8 channel)
- Lead-Acid battery (16 channel)
- External power input 12 to 18 Vdc
- DataTran software included
- Communication cable included
Specifications
- Operating temp. 5 to 104°F
- Accuracy ±0.2% FS
- Resolution ±0.015% FS
- Input standard 4–20 mA probes
- Alarm contact 30 V (AC or DC)
- Alarm contact 1 Amp maximum
- Capacity 4 channel 128,000 points
- Capacity 8 channel 256,000 points
- Capacity 16 channel 256,000 points
- Dimensions 16" x 10" x 11" (all)
- Weight 23.6 lbs. (all)
Ranges
Linear Rate
Log Rate
- 0.5 sec from 0 to 20 sec
- 1 sec from 20 to 60 sec
- 12 sec from 60 to 600 sec
- 2 min from 10 to 100 min
- 20 min from 100 to 1K min
- 200 min from 1K to 10K min
- 1440 min from 10,000 min
Maximum Interval
- 1 min to 24 hrs after 10 min
In-Situ Hermit 1000C
2 Channel Datalogger
A two-channel version of the Hermit, this model also allows for a push-button step test.
Features
- Record up to 2 channels
- Perform aquifer tests
- Linear and Logarithmic tests
- Alkaline battery
- External power input 12 to 18 Vdc
- DataTran software included
- Communication cable included
Specifications
- Operating temp. 5 to 104°F
- Accuracy ±0.2% FS
- Resolution ±0.15% FS
- Input standard 4–20 mA probes
- Capacity 16,000 points
- Dimensions 11" x 7" x 9"
- Weight 12 lbs.
Ranges
Linear Rate
Log Rate
- 0.5 sec from 0 to 20 sec
- 1 sec from 20 to 60 sec
- 12 sec from 60 to 600 sec
- 2 min from 10 to 100 min
- 20 min from 100 to 1K min
- 200 min from 1K to 10K min
- 1440 min from 10,000 min
Maximum Interval
- 1 min to 24 hrs after 10 min
Search Terms: In-Situ Hermit 3000, In Situ Hermit 3000, InSitu Hermit 3000, In-Situ Hermit SE2000, In Situ Hermit SE2000, InSitu Hermit SE2000, In-Situ Hermit 1000C, In Situ Hermit 1000C, InSitu Hermit 1000C (for our search engine)