Thermo Standard Diffusion Transmitter
Fixed Gas Sensor
The Standard Diffusion Transmitter is the most common sensor used when configuring a complete fixed gas detection system. Their 4 to 20 mA output can connect to various monitoring and control systems. Each sensor is housed in a weatherproof rugged enclosure and features easy calibration. Each sensor acts as a single point and when combined with a suitable controller can create endless configurations, from simple single point installations, to large entire complex monitoring systems. Using standard technology, electrochemical for toxic and O2 sensors, wheatstone bridge circuits for combustible sensors, Thermo’s standard diffusion transmitters are designed for durabililty and long life.
This sensor is compatible with Thermo’s Safe T Net line of controllers, including the Safe T Net 100, Safe T Net 210, Safe T Net 410, and Safe T Net 2000.
Thermo Standard Diffusion Sensor Ranges
The Standard Diffusion Transmitter can be configured to detect the following gasses:
| Gas | Sensor Type | Formula | Standard Range |
|---|---|---|---|
| Ammonia | Electrochemical | NH3 | 0 to 100 ppm |
| Carbon Monixide | Electrochemical | CO | 0 to 500 ppm |
| Carbon Dioxide | Electrochemical | CO2 | 0 to 5000 ppm 0 to 1% Volume 0 to 5% Volume |
| Chlorine | Electrochemical | Cl2 | 0 to 10.0 ppm |
| Fluorine | Electrochemical | F2 | 0 to 10.0 ppm |
| Combustible | Catalytic | 0 to 100% LEL 0 to 5000 ppm |
|
| Hydrogen Chloride | Electrochemical | HCl | 0 to 30.0 ppm |
| Hydrogen Fluoride | Electrochemical | HF | 0 to 10.0 ppm |
| Hydrogen Sulfide | Electrochemical | H2S | 0 to 100 ppm |
| Oxygen | Electrochemical | O2 | 0 to 30.0% Volome |
| Sulfur Dioxide | Electrochemical | SO2 | 0 to 20.0 ppm |
Thermo Standard Diffusion Gas Transmitter
Call to Order
1-888-234-5678
| Part No. | Description | Price |
|---|---|---|
| 65-5001 | Standard diffusion transmitter1, combustible | Call to Order |
| 67-0002 | Standard diffusion transmitter2, CO2 | Call to Order |
| 67-0003 | Standard diffusion transmitter3, CO2 | Call to Order |
| 67-0004 | Standard diffusion transmitter4, CO2 | Call to Order |
| 67-0027-01 | Standard diffusion transmitter, CO | Call to Order |
| 67-0027-02 | Standard diffusion transmitter, H2S | Call to Order |
| 67-0027-03 | Standard diffusion transmitter, O2 | Call to Order |
| 67-0027-04 | Standard diffusion transmitter, Cl2 | Call to Order |
| 67-0027-05 | Standard diffusion transmitter, HCl | Call to Order |
| 67-0027-06 | Standard diffusion transmitter, HF | Call to Order |
| 67-0027-09 | Standard diffusion transmitter, NH3 | Call to Order |
| 67-0027-17 | Standard diffusion transmitter, SO2 | Call to Order |






